FR
  • English
Se Connecter

Factory Reset (MMU)

Menu
Pertinent pour:
Dernière mise à jour 9 months ago
Cette article est également disponible dans les langues suivantes : 
EN
This procedure is the same for the MMU3 and MMU2S units running firmware 3.0.0 or newer. In case you are running MMU2S with older FW, please go to Réinitialisation usine (MMU2S pré-firmware 1.0.6).

When upgrading the MMU2S firmware from firmware 1.0.6 (or lower) to 3.0.0 (or higher), or when you find a severe issue with the MMU, you might need to perform a factory reset.

  1. On the MMU unit, hold the left side button and reset the unit by pushing the button on the right side of the MMU with an Allen key.
  1. Keep the left side button pressed for a few seconds. You will see the LEDs on the MMU flashing quickly in a "snake" motion.
  2. Release the MMU left-side button. As soon as you release it, the MMU EEPROM will be cleared and overwritten with factory default values and will do the selftest.

You have successfully reset the MMU. No indication will be shown on the MMU or on the printer.

Cet article vous a-t-il été utile ?

Commentaires

Vous avez encore des questions ?

Vous avez encore des questions ?

Si vous avez une question sur un sujet qui n'est pas traité ici, consultez nos ressources supplémentaires.
Et si cela ne suffit pas, vous pouvez envoyer une demande à [email protected] ou via le bouton ci-dessous.

Nous contacter